TTC MSCW-606D Wideband Acquisition Module

  • Downloads
  • SPECIFICATIONS
  • SUPPORT
  • REQUEST A QUOTE

Features

  • Channel sample rates available at up to 100 ksps
  • Simultaneous Sampling capability, with thinning option
  • Programmable digital FIR or IIR presample filtering
    • Automatic adaptive filter -3dB frequency based on format sample rate or direct selection of filter -3dB frequency on a per channel basis
    • 7-pole analog anti-aliasing filter eliminates possibility of signal aliasing
  • RMS data output on a per channel basis
    Programmable gain and offset >10,000 settings from 1 to 2000
  • Automatic parasitic offset correction on power up and ZCAL (CAL1). Programmable voltage excitation.

Applications

  • Flight test instrumentation
  • Factory automation and process control
  • Research measurements and experiments
Miniature Enhanced Data Acquisition Unit

TTC MEDAU-20XX Miniature Enhanced Data Acquisition Unit

The TTC MEDAU-20XX is a miniature, E-Bus compatible Data Acquisition Unit (DAU) for interfacing with a variety of analog/digital sensors and sources. The system is reconfigurable to handle...

Miniature Wide-band Data Acquisition Unit

TTC MWDAU-20XX 20 Mbps Miniature Wide-band Data Acquisition Unit

The TTC MWDAU-20XX is a miniature, CAIS compatible Wideband DAU for interfacing a variety of analog/digital sensors, and encoding these sources into a wideband PCM output data stream up to 20 Mbps....

CONTACT SALES/SUPPORT

We’d like to keep in touch and send you updates on our products, news and developments – please tick below to make sure you don’t miss out. You can unsubscribe at any time by clicking on the unsubscribe link at the bottom of the emails. Your personal information will not be shared with any person or organization outside of Curtiss-Wright. Review our privacy policy.


The MSCW-606D-1 is a 6-channel signal conditioning module for use in the TTC MEDAU, MCDAU, MWDAU and MnACQ-2000 products. The module is intended for a variety of applications and thus provides significant signal conditioning flexibility. The MSCW-606D-1 is compatible with ICP type accelerometers as well as numerous bridge and potentiometer input sensor configurations.

It provides AC and DC input coupling, constant current and constant voltage excitation, programmable presample filtering, calibration, auto-balance, and user programmable gain and offset. Numerous configurations of FIR or IIR digital presample filtering may be software selected with a wide range of cutoff frequencies. In addition, RMS output data is computed by the onboard DSP based on a given channels channel sample rate and user selectable integration time.

Product Finder

Connect With Curtiss-Wright Connect With Curtiss-Wright Connect With Curtiss-Wright
Sales

CONTACT SALES

Contact our sales team today to learn more about our products and services.

YOUR LOCATION

PRODUCT INFORMATION

Support

GET SUPPORT

Our support team can help answer your questions - contact us today.

REQUEST TYPE

SELECT BY

SELECT Topic